Engineered solutions
for your home and your company

Manhole covers

Biocent has designed a wide range of manhole covers to meet clients' expectations. Our manhole covers are made of stainless steel 3 mm thick, which increases the general endurance as well as prevents from installation caused deformations. We provide various sizes and types of manhole covers.

Apart from standard options, there is an option of producting manhole covers based on individual projects.

FLOOR MANHOLE COVER FOR BKP TILING

Separatory koalescencyjne z betonu BIOSEP-C Separatory koalescencyjne z betonu BIOSEP-C

Material: Our manholes are made of stainless steel, 3 mm thick, which increases the general endurance as well as the endurance to installation caused deformations.

Endurance: 15 kN. The manhole cover should be filled with concrete type C50/60, at least 40 mm thick. It is reinforced inside with 4 mm rods.

Tightness: applied EPDM gasket which appropriately pressed gives us full waterproof and odour- free design. In case of exceptional circumstances, there is possibility of applying additional gaskets.

COVER TYPE CLEARANCE AxB OUTSIDE DIMENSIONS ExS HEIGHT H
  [mm] [mm] [mm]
BKP200x200 200x200 300x300 60/80
BKP300x300 300x300 400x400 60/80
BKP400x400 400x400 500x500 60/80
BKP500x500 500x500 600x600 60/80
BKP600x600 600x600 700x700 60/80
BKP700x700 700x700 800x800 60/80
BKP800x800 800x800 900x900 60/80
BKP900x900 900x900 1000x1000 60/80
BKP1000x1000 1000x1000 1100x1100 60/80
Separatory koalescencyjne z betonu BIOSEP-C Separatory koalescencyjne z betonu BIOSEP-C

There is an option of producing manhole covers in other dimensions

Floor manhole cover for BKP tiling

MANHOLE COVER FOR BKB PAVING

Separatory koalescencyjne z betonu BIOSEP-C Separatory koalescencyjne z betonu BIOSEP-C

Material: Our hatches are made of stainless steel, 3 mm thick, which increases the general endurance as well as the endurance to installation caused deformations.

Endurance: 125 kN. The hatch should be filled with concrete type C50/60, at least 60 mm thick. It is reinforced inside with 6 mm rods.

Tightness: applied EPDM gasket which appropriately pressed will give us full waterproof and odour-free design. In case of exceptional circumstances, there is possibility of applying additional gaskets.

HATCH TYPE CLEARANCE AxB OUTSIDE DIMENSION ExS HEIGHT H
  [mm] [mm] [mm]
BKB200x200 200x200 300x300 100/120
BKP300x300 300x300 400x400 100/120
BKP400x400 400x400 500x500 100/120
BKP500x500 500x500 600x600 100/120
BKP600x600 600x600 700x700 100/120
BKP700x700 700x700 800x800 100/120
BKP800x800 800x800 900x900 100/120
BKP900x900 900x900 1000x1000 100/120
BKP1000x1000 1000x1000 1100x1100 100/120
Separatory koalescencyjne z betonu BIOSEP-C Separatory koalescencyjne z betonu BIOSEP-C

There is an option of producing hatches in other dimensions

Manhole cover for BKB paving

FLOOR MANHOLE COVER FOR BKPO TILING WITH INSULATION

Separatory koalescencyjne z betonu BIOSEP-C Separatory koalescencyjne z betonu BIOSEP-C

Material: Our manholes are made of stainless steel, 3 mm thick, which increases the general endurance as well as the endurance to installation caused deformations.

Endurance: 15 kN. The manhole cover should be filled with concrete type C50/60, at least 40 mm thick. It is reinforced inside with 4 mm rods.

Tightness: Tightness: applied EPDM gasket which appropriately pressed will give us full waterproof and odour-free design. In case of exceptional circumstances, there is possibility of applying additional gaskets

Insulation: with 50 mm thick styrodur

COVER TYPE CLEARANCE AxB OUTSIDE DIMENSIONS ExS HEIGHT H
  [mm] [mm] [mm]
BKB200x200 200x200 300x300 60/80
BKP300x300 300x300 400x400 60/80
BKP400x400 400x400 500x500 60/80
BKP500x500 500x500 600x600 60/80
BKP600x600 600x600 700x700 60/80
BKP700x700 700x700 800x800 60/80
BKP800x800 800x800 900x900 60/80
BKP900x900 900x900 1000x1000 60/80
BKP1000x1000 1000x1000 1100x1100 60/80
Separatory koalescencyjne z betonu BIOSEP-C Separatory koalescencyjne z betonu BIOSEP-C

There is an option of producing manholes in other dimensions

Floor manhole cover for BKPO tiling with insulation

MANHOLE COVER FOR BKBO PAVING WITH INSULATION

Separatory koalescencyjne z betonu BIOSEP-C Separatory koalescencyjne z betonu BIOSEP-C

Material: Our manholes are made of stainless steel, 3 mm thick, which increases the general endurance as well as the endurance to installation caused deformations.

Endurance: 125 kN. The manhole cover should be filled with concrete type C50/60, at least 60 mm thick. It is reinforced inside with 4 mm rods.

Tightness: applied EPDM gasket which appropriately pressed will give us full waterproof and odour-free design. In case of exceptional circumstances, there is possibility of applying additional gaskets.

Insulation: with 50 mm thick styrodur

COVER TYPE CLEARANCE AxB OUTSIDE DIMENSIONS ExS HEIGHT H
  [mm] [mm] [mm]
BKB200x200 200x200 300x300 100/120
BKP300x300 300x300 400x400 100/120
BKP400x400 400x400 500x500 100/120
BKP500x500 500x500 600x600 100/120
BKP600x600 600x600 700x700 100/120
BKP700x700 700x700 800x800 100/120
BKP800x800 800x800 900x900 100/120
BKP900x900 900x900 1000x1000 100/120
BKP1000x1000 1000x1000 1100x1100 100/120
Separatory koalescencyjne z betonu BIOSEP-C Separatory koalescencyjne z betonu BIOSEP-C

There is an option of producing manholes in other dimensions

Manhole cover for BKBO paving with insulation

FLOOR MANHOLE COVER FOR BKPP TILING WITH FIRE PROTECTION

Separatory koalescencyjne z betonu BIOSEP-C Separatory koalescencyjne z betonu BIOSEP-C

Material: Our manholes are made of stainless steel, 3 mm thick, which increases the general endurance as well as the endurance to installation caused deformations.

Endurance: 15 kN. The manhole cover should be filled with concrete type C50/60, at least 40 mm thick. It is reinforced inside with 4 mm rods.

Tightness: applied EPDM gasket which appropriately pressed will give us full waterproof and odour-free design. In case of exceptional circumstances, there is possibility of applying additional gaskets.

Fire protection: applied flame protection panels EI 60, 40mm thick and a gasket.

COVER TYPE CLEARANCE AxB OUTSIDE DIMENSIONS ExS HEIGHT H
  [mm] [mm] [mm]
BKB200x200 200x200 300x300 60/80
BKP300x300 300x300 400x400 60/80
BKP400x400 400x400 500x500 60/80
BKP500x500 500x500 600x600 60/80
BKP600x600 600x600 700x700 60/80
BKP700x700 700x700 800x800 60/80
BKP800x800 800x800 900x900 60/80
BKP900x900 900x900 1000x1000 60/80
BKP1000x1000 1000x1000 1100x1100 60/80
Separatory koalescencyjne z betonu BIOSEP-C Separatory koalescencyjne z betonu BIOSEP-C

There is an option of producing manhole covers in other dimensions

Floor manhole cover for BKPP tiling with fire protection

MODULAR MANHOLE COVER FOR BKP-M TILING

Separatory koalescencyjne z betonu BIOSEP-C

Material: Our manholes are made of stainless steel, 3 mm thick, which increases the general endurance as well as the endurance to installation caused deformations.

Endurance: 15 kN. The manhole cover should be filled with concrete type C50/60, at least 40 mm thick. It is reinforced inside with 4 mm rods.

Tightness: applied EPDM gasket which appropriately pressed will give us full waterproof and odour-free design. In case of exceptional circumstances, there is possibility of applying additional gaskets.

Any dimension: thanks to modular construction

COVER TYPE CLEARANCE AxB OUTSIDE DIMENSIONS ExS SEGMENTS NUMBER HEIGHT*
  [mm] [mm]   [mm]
BKP-M600x1200 600x1200 700x1300 2 60/80
BKP-M600x1800 600x1800 700x1900 3 60/80
BKP-M800x1600 800x1600 900x1700 2 60/80
BKP-M800x2400 800x2400 900x2500 3 60/80
BKP-M1000x2000 1000x2000 1100x2100 2 60/80
BKP-M1000x3000 1000x3000 1100x3100 3 60/80
BKP-M1200x1200 1200x1200 1300x1300 4 60/80
BKP-M1200x1800 1200x1800 1300x1900 6 60/80
BKP-M1600x2400 1600x2400 1700x2500 6 60/80
Separatory koalescencyjne z betonu BIOSEP-C

There is an option of producing manholes in other dimensions

Modular manhole cover for BKP-M tiling

MODULAR MANHOLE COVER FOR CONCRETE FILLING OR BKB-M PAVING

Separatory koalescencyjne z betonu BIOSEP-C Separatory koalescencyjne z betonu BIOSEP-C

Material: Our manhole covers are made of stainless steel, 3 mm thick, which increases the general endurance as well as the endurance to installation caused deformations.

Endurance: 15 kN. The manhole cover should be filled with concrete type C50/60, at least 40 mm thick. It is reinforced inside with 10 mm rods.

Tightness: applied EPDM gasket which appropriately pressed will give us full waterproof and odour-free design. In case of exceptional circumstances, there is possibility of applying additional gaskets.

Any dimension: thanks to modular construction

COVER TYPE CLEARANCE AxB OUTSIDE DIMENSIONS ExS SEGMENTS NUMBER HEIGHT*
  [mm] [mm]   [mm]
BKP-M600x1200 600x1200 700x1300 2 100/120
BKP-M600x1800 600x1800 700x1900 3 100/120
BKP-M800x1600 800x1600 900x1700 2 100/120
BKP-M800x2400 800x2400 900x2500 3 100/120
BKP-M1000x2000 1000x2000 1100x2100 2 100/120
BKP-M1000x3000 1000x3000 1100x3100 3 100/120
BKP-M1200x1200 1200x1200 1300x1300 4 100/120
BKP-M1200x1800 1200x1800 1300x1900 6 100/120
BKP-M1600x2400 1600x2400 1700x2500 6 100/120
Separatory koalescencyjne z betonu BIOSEP-C

There is an option of producing covers in other dimensions

Manhole cover for BKBO paving with insulation

MANHOLE COVER FOR FILLING WITH BKS ACTUATORS

Separatory koalescencyjne z betonu BIOSEP-C

Material: Our manhole covers are made of stainless steel, 3 mm thick, which increases the general endurance as well as the endurance to installation caused deformations while opening even a big cover is no problem due to application of actuators.

Endurance: 125 kN. The manhole cover should be filled with concrete type C50/60, at least 40 mm thick. It is reinforced inside with 6 mm rods.

Tightness: applied EPDM gasket which appropriately pressed will give us full waterproof and odour-free design. In case of exceptional circumstances, there is possibility of applying additional gaskets.

COVER TYPE CLEARANCE AxB OUTSIDE DIMENSIONS ExS HEIGHT H
  [mm] [mm] [mm]
BKB200x200 200x200 300x300* 60/80/100/120
BKP300x300 300x300 400x400* 60/80/100/120
BKP400x400 400x400 500x500* 60/80/100/120
BKP500x500 500x500 600x600* 60/80/100/120
BKP600x600 600x600 700x700* 60/80/100/120
BKP700x700 700x700 800x800* 60/80/100/120
BKP800x800 800x800 900x900* 60/80/100/120
BKP900x900 900x900 1000x1000* 60/80/100/120
BKP1000x1000 1000x1000 1100x1100* 60/80/100/120
Separatory koalescencyjne z betonu BIOSEP-C

There is an option of producing covers in other dimensions

Manhole cover for filling with BKS actuators

MANHOLE COVER FOR FILLING WITH BKS ACTUATORS

Separatory koalescencyjne z betonu BIOSEP-C Separatory koalescencyjne z betonu BIOSEP-C

Material: Our manhole covers are made of stainless steel, 3 mm thick, which increases the general endurance as well as the endurance to installation caused deformations while opening even a big hatch is no problem due to application of actuators.

Endurance: 125 kN. The hatch should be filled with concrete type C50/60. It is reinforced inside with 6 mm rods.

Tightness: applied EPDM gasket which appropriately pressed will give us full waterproof and odour-free design. In case of exceptional circumstances, there is possibility of applying additional gaskets.

COVER TYPE CLEARANCE AxB OUTSIDE DIMENSION ExS HEIGHT H
  [mm] [mm] [mm]
BKK300x300 300x300/td> 400x400 40
BKK400x400 400x400 500x500 40
BKK500x500 500x500 600x600 40
BKK600x600 600x600 700x700 40
BKK700x700 700x700 800x800 40
BKK800x800 800x800 900x900 40
BKK900x900 900x900 1000x1000 40
BKK1000x1000 1000x1000 1100x1100 40
BKK12000x12000 1200x1200 1300x1300 40
Separatory koalescencyjne z betonu BIOSEP-C Separatory koalescencyjne z betonu BIOSEP-C

There is an option of producing manhole covers in other dimensions

Manhole cover for filling with BKS actuators

INDIVIDUAL PRODUCTS

We also produce non-standard products on request:

Photos of chosen realizations:

Separatory koalescencyjne z betonu BIOSEP-C Separatory koalescencyjne z betonu BIOSEP-C

Galvanized platform in a pumping station

Stainless switch boxes



Separatory koalescencyjne z betonu BIOSEP-C Separatory koalescencyjne z betonu BIOSEP-C

Platform gratings and manhole covers – underground station ONZ Roundabout, Warsaw


Separatory koalescencyjne z betonu BIOSEP-C Separatory koalescencyjne z betonu BIOSEP-C

Manhole covers – Okęcie Airport, Warsaw

Contact us today

Do you have any questions? Our team of specialists will answer all your questions.

Western region:

Rafał Synowiec
e-mail: poznan@biocent.pl
tel. 512-238-818

Damian Lasota
e-mail: damian@biocent.pl
tel. 789-191-799

Sławomir Olejniczak
e-mail: poznan@biocent.pl

South-Eastern region:

Tomasz Masłowski
e-mail: tomasz@biocent.pl
tel. 504-307-609

Paweł Bury
e-mail: pawel@biocent.pl
tel. 517-466-370

Biocent sp. z o. o.

ul. Do Dysa 5
20-149 Lublin, POLAND
e-mail: biuro@biocent.pl
tel. 517-466-370

North-Eastern region:

Customer Service
e-mail: bialystok@biocent.pl
tel. 504-307-609
tel. 517-763-212

Do you need
professional?
Realizacja Agencja interaktywna PROPERIS