Manhole for fire protection filling BIOTOP-PP

Material:
Our hatches are made of stainless steel with a thickness of 3 mm, which increases their strength and resistance to deformation during installation.

Strength:
The hatch should be filled with concrete C40/50; additionally, there is reinforcement with rods inside the flap.

Sealing:
The use of a special gasket, which is properly pressed under the weight of the hatch, gives us full water resistance and odor tightness. 2x lifting screw Fire protection EIR 120, A1 confirmed by tests of an independent notifying unit

H=60 mm A15 kNH=80 mm A15 kNH=100 mm B125 kNH=120 mm C250 kN
Typ włazuPrześwit AxBWymiar zewnętrzny ExSMasa włazu (koryto)Masa włazu z wypełnieniemMasa włazu (koryto)Masa włazu z wypełnieniemMasa włazu (koryto)Masa włazu z wypełnieniemMasa włazu (koryto)Masa włazu z wypełnieniem
[mm][mm][kg][kg][kg][kg][kg][kg][kg][kg]
BIOTOP-PP 200x200200x200300x300412416520624
BIOTOP-PP 300x300300x300400x400622729836943
BIOTOP-PP 400x400400x400500x500934104511561267
BIOTOP-PP 500x500500x500600x6001250136515811697
BIOTOP-PP 600x600600x600700x700166818891911020132
BIOTOP-PP 700x700700x700800x8002189221172414525173
BIOTOP-PP 800x800800x800900x90026112281482918331219
BIOTOP-PP 900x900900x9001000x100032139331833522637270
BIOTOP-PP 1000x10001000x10001100x110038168402214227444327
BKPP niest.AxBExS=(A+100) x(B+100)doust.doust.doust.doust.doust.doust.doust.doust.